this post was submitted on 26 Jun 2025
195 points (93.7% liked)

Mildly Infuriating

40688 readers
1007 users here now

Home to all things "Mildly Infuriating" Not infuriating, not enraging. Mildly Infuriating. All posts should reflect that.

I want my day mildly ruined, not completely ruined. Please remember to refrain from reposting old content. If you post a post from reddit it is good practice to include a link and credit the OP. I'm not about stealing content!

It's just good to get something in this website for casual viewing whilst refreshing original content is added overtime.


Rules:

1. Be Respectful


Refrain from using harmful language pertaining to a protected characteristic: e.g. race, gender, sexuality, disability or religion.

Refrain from being argumentative when responding or commenting to posts/replies. Personal attacks are not welcome here.

...


2. No Illegal Content


Content that violates the law. Any post/comment found to be in breach of common law will be removed and given to the authorities if required.

That means: -No promoting violence/threats against any individuals

-No CSA content or Revenge Porn

-No sharing private/personal information (Doxxing)

...


3. No Spam


Posting the same post, no matter the intent is against the rules.

-If you have posted content, please refrain from re-posting said content within this community.

-Do not spam posts with intent to harass, annoy, bully, advertise, scam or harm this community.

-No posting Scams/Advertisements/Phishing Links/IP Grabbers

-No Bots, Bots will be banned from the community.

...


4. No Porn/ExplicitContent


-Do not post explicit content. Lemmy.World is not the instance for NSFW content.

-Do not post Gore or Shock Content.

...


5. No Enciting Harassment,Brigading, Doxxing or Witch Hunts


-Do not Brigade other Communities

-No calls to action against other communities/users within Lemmy or outside of Lemmy.

-No Witch Hunts against users/communities.

-No content that harasses members within or outside of the community.

...


6. NSFW should be behind NSFW tags.


-Content that is NSFW should be behind NSFW tags.

-Content that might be distressing should be kept behind NSFW tags.

...


7. Content should match the theme of this community.


-Content should be Mildly infuriating.

-The Community !actuallyinfuriating has been born so that's where you should post the big stuff.

...


8. Reposting of Reddit content is permitted, try to credit the OC.


-Please consider crediting the OC when reposting content. A name of the user or a link to the original post is sufficient.

...

...


Also check out:

Partnered Communities:

1.Lemmy Review

2.Lemmy Be Wholesome

3.Lemmy Shitpost

4.No Stupid Questions

5.You Should Know

6.Credible Defense


Reach out to LillianVS for inclusion on the sidebar.

All communities included on the sidebar are to be made in compliance with the instance rules.

founded 2 years ago
MODERATORS
 

Those aren't supposed to be round on top.

you are viewing a single comment's thread
view the rest of the comments
[–] [email protected] 10 points 5 days ago (11 children)
[–] [email protected] 27 points 5 days ago (10 children)

Motor capacitor for an A/C compressor. A $15 part that a service company is going to charge $400 for a guy missing most of his teeth to replace in 2 minutes.

[–] [email protected] 14 points 5 days ago* (last edited 5 days ago) (1 children)

When I used to fix cars for a dealership we would sometimes have the service advisor ask us to do work for free. "Come on, it'll just take you ten minutes!"

I'd tell them that they can do it themselves if it only takes ten minutes. "But I don't know how to do that!"

You're not just paying for the part, you're paying for the knowledge, time, and tools of the technician.

[–] [email protected] 7 points 5 days ago (1 children)

And to be completely honest, if you call an HVAC repair company, they're likely to do a whole PM cycle on it. Flush the condensate line and pan, clean the coils and the heat exchanger, replace the contactor if you have one, take the temperature differential to make sure the unit is operating reasonably well, replace the blower belt it's not direct drive. I PM the unit myself every spring and fall. I probably should have had eyes on that cap though.

[–] [email protected] 2 points 4 days ago* (last edited 4 days ago) (1 children)

Yeah, testing caps is also a pretty regular part of our PM process. Especially because that one looks like it may partially be a run cap and a system can often run perfectly fine without a run cap except it will cause the motor to pull higher amps and run hotter. Catching a bad run cap early is the difference between replacing a bad cap and replacing a burned up motor.

Edit: Although you're already doing far more for your system than most. I'm an actual tech and it's been a shamefully long time since my equipment at home has had a full PM done.

[–] [email protected] 2 points 4 days ago (1 children)

That's good to hear, thanks for that. Yes it's a dual cap. I'll have to dig out my LC meter and add that to my list.

It was a new build, my old plays I didn't stay on top of things and ended up paying for it. I decided to do a better job here.

My very first maintenance I went down to look at what I needed to do. It's a trane unit, so the evaporator coil and the condensate pan come out on a slide which is pretty fancy. The condensate line, combustion and exhaust air are all PVC and they glued it all so you couldn't get the tray out. (The air lines don't even go into the box they just ran it past the front for spite I think)

Hope you don't mind if I ask you two questions, not holding you accountable or anything.

What are you guys using for condenser coil cleaner? I just got some off-the-shelf home Depot stuff but it looks sus. I pulled the case and separated the coils out at the two-year mark and followed the instructions on the cleaner. I didn't see any physical dirt anywhere and there's no leaves or debris. Without physical dust dirt or debris do you think just hosing it down from the outside on PM is fine?

[–] [email protected] 1 points 3 days ago (1 children)

My very first maintenance I went down to look at what I needed to do. It's a trane unit, so the evaporator coil and the condensate pan come out on a slide which is pretty fancy.

If it's the style I'm thinking of then you are flexing the refrigerant pipes whenever you do that. It's designed to do that but just be aware that copper work hardens so you can only flex it so many times before it gets brittle and snaps. With your system being new there isn't too much risk of snapping a line but it won't be new forever. If it is possible to clean the evap without bending those pipes then that is the best way to do it.

As far as coil cleaner goes the most we ever recommend one of our customers use is just plain water out of a gardenhose (definitely not a pressurewasher). For most people that should be enough. But you're not my customer so here's what I use depending on the coil.

For small evap coils like a residential central air system I often use Evap Foam No Rinse. That stuff is pretty gentle and probably fine for most people to use. If kills any growth on the coil and foams up to push dirt out of the coil. Once applied it doesn't need to be actively rinsed off because it's designed to be rinsed off just by the condensation that builds up on the coil as the system runs.

For larger evap coils like in commercial roof top units or more heavily soiled evaps I will use either Tri-Pow'r HD or Evap Pow'r-C. I've found both to be about equally as effective but the evap cleaner does foam up a bit more. Both are still fairly safe to use but if you mix them more concentrated then you do need to actively rinse off the coil well when you're done. I have a hard time imagining anyone breaking anything with either of these but technically they can do damage if left on the coil for too long.

When it comes to the new style microchannel condensers, heavily degraded older style fin and tube condensers, or lightly soiled older style condensers, I will also use Tri-Pow'r HD except I will mix it much stronger.

When it comes to heavily soiled older style fin and tube condensers which are otherwise in good physical shape I will use Nu-Brite. Nu-Brite is nasty shit. It will instantly burn skin, melt plastic, strip any oxidation off of metal, etch concrete, strip paint, strip the coating entirely off a coated coil, and, if left on a coil long enough, etch holes through the condenser pipes forcing you to buy a whole new condensing unit. It literally starts to smoke if it sits on the coil too long. It is aggressive as hell but man does it clean coils. I was working at a flour mill recently and made extensive use of this stuff to clean mouldering packed in flour mud out of condensers and it takes no time at all to do it's job even with the worst soils. This stuff is perfectly safe to use if you use it right but if you don't use it right then there is basically no fixing the damage it does. If you ever did decide to use it, just be sure to have a hose nearby ready to hose it off as quick and completely as possible. Once it starts foaming and smoking it has started doing damage.

[–] [email protected] 2 points 3 days ago (1 children)

Thank you so much taking the time to write all that, its truly useful information.. I would have completely overlooked the no rinse stuff for fear it was a sales gimmick.

I think I'll probably hose wash down every season, foam it If the water coming off has anything in it and save the teardown for 5-year or special event.

There's not really much here in the way of sand or dust. It's mounted off the ground. The hose should be able to get smoke particulate and pollen off.

Thanks again.

[–] [email protected] 2 points 3 days ago

Not a problem. In my area the bug thing is cottonwood. If you dont have that stuff around the coils stay much easier to clean.

load more comments (8 replies)