You can easily do that with some extra key bindings and channel commanders/whisper groups
Sleepkever
It is not, but a write amplification of 36704:1 is one hell of an exploitable surface.
With that same Raspberry Pi and a single 1gbit connection you could also do 333333 post requests of 3 KB in a single second made on fake accounts with preferably a fake follower on a lot of fediverse instances. That would result in those fediverse servers theoretically requesting 333333 * 114MB = ~38Gigabyte/s. At least for as long as you can keep posting new posts for a few minutes and the servers hosting still have bandwidth. DDosing with a 'botnet' of fediverse servers/accounts made easy!
I'm actually surprised it hasn't been tried yet now that I think about it...
You might want to try out ZHA then. Its a bit younger so it doesn't support lesser known devices that z2m does and it has its quirks with other devices. But it comes almost out of the box with HA and is a 1 click install. The latest HA update brought firmware updates to the frontend, but I believe z2m already had that for a while.
I have been running zha for half a year with some Ikea lights and some nous smart plugs and the only moment it has misbehaved is when the power to one of the router nodes went out and it stopped sending zigbee messages to certain other nodes.
It's the other way around. Companies in the Netherlands lease cars for their employees here in the Netherlands. Usually for people that travel a lot with for their job or just as a bonus perk that comes with the job instead of salary. And the boss pays for all the gas and maintenance as well.
So either take the effort to charge, or even charge at home and get refunded the electricity costs. Or just fill it up with free gas which only takes a minute. Guess which happens the most?
The only time I saw some of those oversized and really popular Mitsubishi Outlander PHEV use a charge cable was if they wanted to take a good parking spot...
The cables in your walls are designed for a certain maximum current before they start to heat up. This current is limited by your breaker.
Now if you introduce a plug in solar setup your current is limited by your maximum breaker capacity + whatever your solar setup can generate.
So if I'd use the specs from the article and apply it to a normal dutch home situation: 16A breaker, + 800W at 230V, which means ~3.5A = 19.5A max. which is probably still fine for short durations.
But now some genius doesn't read the fine print and hooks up 2 or 3 on the same circuit. There is no electrician that tells him that's dangerous because it's all self installed and he doesn't know any better. And all of a sudden you are up to 26.5A and you got glowing, smoking wires in your walls...